ReadyMadeRC
Hitec X4 AC Plus 4 Port ACDC Multi-Charger
Stock# 44167:, Hitec X4 AC Plus AC/DC Four-Channel Multi-Charger, Input Requirements:, 100-120V AC or 12 - 15 Volts DC, 20 Amp Minimum, : Reduces charging time, but does not balance the cells, this mode only charges the battery to approximately 90% capacity., : Monitors individual cell voltage, keeping the cells within an acceptable voltage range and charges the pack to peak capacity., : Used for long-term battery storage. Adjusts the voltage level so the battery will not be damaged during long term storage., Includes:, X4 Charger,
We raised the bar on the X4 and equipped it with a built-in AC power supply. Our new X4 AC Plus, has four-port computer controlled capability with a built-in 22 amp power supply which can be powered by standard 120 volt AC household current. Simple to use and utterly reliable, this compact charger with battery management and integral balancer features four identical and independent 50-watt power outputs, for a total output power of 200 watts. Each port of the X4 AC Plus can handle up to a 6S Lithium pack, 15 NiCd/NiMH cells or 6-12 volt lead acid batteries. Four individual balancing ports eliminate the need for a separate balancer when charging Lithium batteries. Its twin fan cooling system with an internal sensor for controlling fan speed provides the utmost in efficiency and safety. The X4 AC Plus can accept a variety of power inputs including the option of attaching it to a 12-volt car battery or a 11–15 volt (20 amp minimum) DC power supply.
The Hitec X4 AC Plus charger offers a complete charging solution for novice and expert RC enthusiasts alike. The multi-tasking versatility of this new charger makes it a perfect fit for nitro and electric modelers, regardless of what you drive, hover, float or fly.
Download the Manual
HERE
Charging Specifications
Battery Type
Number of Cells
Voltage Level
Max. Charge Voltage
Max. Fast Charge Rate
Min. Discharge Voltage
NiCd
1 - 15
1.2V / Cell
1.5V / Cell
1 - 2C*
0.85V / Cell
NiMh
1 - 15
1.2V / Cell
1.5V / Cell
1 - 2C*
1.0V / Cell
Li-Ion
1 – 6
3.6 / Cell
4.1V / Cell
1C
2.5V / Cell
LiPo
1 – 6
3.7V / Cell
4.2V / Cell
1C
3.0V / Cell
LiFe
1 – 6
3.3V / Cell
3.6V / Cell
4C
2.0V / Cell
Pb (Lead Acid)
1 - 10
2.0V / Cell
2.46V / Cell
0.4C
1.75V / Cell
SPECIAL FEATURES
Optimized Operating Software
The software in X4 AC Plus automatically controls the current rate during the charging or discharging process. This feature can prevent the user from overcharging their batteries which could lead to damage or injury. If the charger detects a malfunction, the circuit automatically disconnects and an alarm will sound, The operating functions of the X4 AC Plus are controlled through a two-way communication link in order to maintain maximum safety with minimal errors. All of these functions and settings are easily configured by the user.
Internal Independent Lithium Battery Balancers
Each channel of the X4 AC Plus employs an individual-cell voltage balancer eliminating the need for an external balancer for balance charging.
Balancing Individual Cells during Battery Discharging
During the process of discharging, the X4 AC Plus can monitor and balance each cell of the lithium battery individually. If the voltage of any single cell is abnormal, an error message will display and the discharge process will automatically end.
Charges Most Popular Lithium Batteries
The X4 AC Plus is compatible with the three most common Lithium chemistry batteries, Li-Ion, LiPo and LiFe
Multiple Lithium Battery Charge Modes
The X4 AC Plus's programming allows for Fast Charge, Balance Charge or Storage Charge Modes for LiPo, Li-Ion, and LiFe batteries.
Fast Charge Mode
Balance Charge Mode
Storage Charge Mode
Delta Peak Technology for Maximum Safety
The automatic charge termination program utilizes Delta-Peak voltage detection. When the battery's voltage exceeds the threshold, the charge process is terminated automatically.
Automatic Charging Current Limit
The maximum charge rate can be manually set when charging NiCd or NiMH batteries. The X4 AC Plus will auto-detect when the batteries are fully charged and shut off, even with low impedance NiMH packs.
Capacity and Processing Time Limit
The charging capacity is calculated as the charging current multiplied by time. If the charging capacity exceeds the maximum limit set by the user, the process will terminate automatically. Additionally the user can set the maximum amount of charging time. If the charging time exceeds this limit, the process will terminate automatically.
Temperature Threshold
The battery's internal chemical reaction causes the temperature of the battery to rise during the charging process. If the temperature exceeds the limit, the charging process will automatically terminate.
* This function is available by connecting an optional temperature probe, which is not included in our package.
5 User Customizable Presets Per Channel
The X4 AC Plus features 5 individually customizable presets so the user can store the charge and discharge parameters for any particular battery type. These presets can be recalled for the desired battery type without the need for any additional programming.
Cyclic Charging / Discharging
Batteries can be set to automatically Charge/Discharge or Discharge/Charge up to a maximum of 5 cycles.
PC Based Analysis Using USB Communication*
The Hitec X4 AC Plus offers a PC-based program which can analyze the characteristics of the battery via a USB port. It shows a graph of voltage, current and capacity curves. It also displays the individual voltage of each cell in the lithium battery pack.
* A PC-LINK USB adaptor can be purchased separately.
US A/C Plug
JST-XH Balace Breakout Board (2s-6s)
TP/FP Balance Breakout Board (2s-6s)
HP/PQ Balance Breakout Board (2s-6s)
12V Power Plug with Alligator Clips
Output Cable with Bare Leads
Output Cable with Molex Plug
Output Cable with XT60 Plug
Output Cable with Servo Plug
Need a different battery plug? Try
this
adapter!.
Check price and availability